File Formats

Data files are organized into records and comments. The observables file is the one file a case needs that is neither: it is described at the end of this page.

Each record includes:

  • A leading keyword that identifies the information provided
  • One or more fields (numeric or character)
  • A terminating semicolon (;) that marks the end of the record
LINE A-B BUS_A BUS_B 3.0 30.0 150.0 1400.0 1 ;

Inside the record, the keyword, fields, and semicolon are separated by at least one space. Anything after the semicolon is ignored. The next record (or comment) starts with the next line.

A record may span multiple lines; the semicolon indicates the end. Spanning over several lines is highly recommended for records that include many fields. Note that, depending on the text editor and its settings, a long record could appear truncated when displayed.

INJEC GFOL VSC1 A 1.0 1.0 0.0 0.0 0.005 0.15 1.02 1200.0 0.005 0.15 0.573 6.0
0.0033 0.0333 10.0 0.002 -999.0 10.0 0.1667 50.0 0.10 0.4 0.5 1.0 -1000. -2000. 1.001 1 ;

Some records have optional fields, which are always located at the end of the record.

Numeric fields are written in free format: with or without a decimal point, with or without an exponent. The exponent can be denoted by E or D:

30 30. 30.0 3E01 3.E01 3.0E01 3.E1 3.e1

All of the above represent the same number.

  • Limited to 20 characters (only first 20 are read; the rest is silently ignored without warning). It is discouraged to have more than 20 characters in a field
  • Some fields are limited to 8 characters (e.g., bus names); characters beyond 8 are ignored
  • Uppercase letters are significant (case-sensitive)
  • If a field includes a space or slash (/), enclose it in quotes (' or "). Between quotes, leading spaces are significant while trailing ones are ignored
  • Keywords do not include spaces, so quoting them is unnecessary
  • The semicolon (;) must not be included in any character field, even within quotes

There are three ways to insert comments:

  1. Exclamation mark (!): A line whose first non-blank character is ! is memorized and reproduced on output (up to 130 characters after the !)
  2. Sharp (#): A line whose first non-blank character is # is completely ignored, useful for field labels
  3. After semicolon: Anything after the ; terminator is ignored
# Example: using # comments to label fields
# name bus FP FQ P Q SNOM RS LLS LSR RR LLR
INJEC INDMACH1 SM 2 0.2 0.2 0. 0. 0. 0.031 0.1 3.2 0.018 0.180
# H A B LF
0.7 0.5 0.0 0.6 ;

Comments do not span multiple lines. If several lines are needed, each must start with ! or #. Empty lines are ignored.

Records may be distributed over an arbitrary number of data files, read sequentially. The order of records inside files does not matter, and the order in which files are read does not matter either.

A typical organization:

  • One file for network data
  • One file for power flow data
  • One file for dynamic component data
  • One file for simulation control parameters

These files can be listed in any order in the command file. The second and third files, for instance, may be swapped in the list without any effect.

The observables file is not a data file. It carries no records, none of the keywords above and no semicolons: it is a plain list, one request per line, naming the equipment whose variables the trajectory file is to contain. STEPSS GUI takes it on the Observables tab, where it is required whenever a trajectory is saved.

Each line is a type and a name:

SYNC g1

The name is the equipment’s own, read into 20 characters and case-sensitive; a longer one is truncated silently. A * in place of a name selects every component of that type.

KeywordSelectsRecorded per component
BUSbuses2: voltage magnitude (pu), phase angle (deg)
SHUNTshunts1: reactive power produced (Mvar)
IMPLOADimpedance loads2: active (MW) and reactive (Mvar) power consumed
BRANCHlines and transformers6: P and Q entering at each end (MW, Mvar), then transformer ratio magnitude and its angle (deg)
SYNCsynchronous machines15, plus whatever the machine’s exciter and torque models publish
INJECinjectorswhatever the injector model publishes
TWOPtwo-port injectorswhatever the two-port model publishes
DCTLdiscrete controllerswhatever the controller publishes

A keyword is read all-uppercase or all-lowercase, so Bus is neither and is rejected. Dynamic loads are injectors and belong under INJEC; IMPLOAD is for the impedance loads alone.

DYNGRAPH lists three of these categories under other names: IMPLOAD appears as LOAD, INJEC as INJ and TWOP as LINK. Those spellings belong to the listing, not to this file.

Two of the types take a three-letter suffix on the keyword, choosing what the recorded numbers mean:

WrittenRecords
BUS-POL, or plain BUSvoltage as magnitude and angle
BUS-RECvoltage as real and imaginary parts (pu)
BRANCH-POW, or plain BRANCHflows as P and Q
BRANCH-CURthe current at each end, as real and imaginary parts (pu)

The suffix does not change how many values are recorded, only what they are.

A line whose first non-blank character is # or ! is ignored, as is an empty line.

# what to record from the Kundur two-area run
SYNC g1
SYNC g2
BUS b7
BUS-REC b9
BRANCH *

At least one request has to be accepted. A file where none is leaves the trajectory without a header, and nothing is recorded.

A scenario file records which files a case is made of, not what is in them. STEPSS GUI writes one with File > Save configuration and reads it back with Load configuration, so a case set up once reopens in two clicks. It is a plain text file and is meant to be writable by hand or by a script.

It carries exactly what the two engines are told to read: the ten system data rows, the disturbance file, the one-line diagram, the observables file, the three run-time observable rows, and the four recording checkboxes. Nothing else, and what is left out is left out on purpose; see What the file deliberately does not carry.

key = value, one per line, UTF-8, with # starting a comment line. Blank lines are ignored. A key that appears twice keeps the last value.

Values are read with Java’s properties parser, so a hand-written file has three rules to respect:

  • = and : both separate a key from its value. A key containing either must escape it; no key defined below does.
  • # and ! start a comment only at the beginning of a line.
  • A backslash escapes: write \\ for a literal backslash, and \t, \n, \r, \f for the control characters. A leading space in a value must be written \ ; spaces anywhere else are literal, which is why runtime.1.type = Bus Voltage needs no quoting.

Windows paths are the case that bites: write C:/cases/lf.dat or C:\\cases\\lf.dat, never C:\cases\lf.dat.

stepss.format is the only mandatory key. Without it the file is refused outright, and no other key in it is read. Every other key is optional to the loader: an absent key means an empty field or a cleared tick, and the load still succeeds. Whether the scenario that comes back can be run is a separate question, answered under What a runnable scenario needs.

KeyRequiredValue
stepss.formatYesFormat number. 1 today
data.1data.10To runThe ten system data rows, in order. Empty rows are not written
disturbanceTo simulateThe disturbance .dst
observables.fileIf recordingThe observables file
diagramNoThe annotated one-line diagram SVG
runtime.1.typeruntime.3.typeNoRun-time plot row: the observable type, by its label (see below)
runtime.1.nameruntime.3.nameNoRun-time plot row: the bus, machine, branch or injector name
record.trajectoryNotrue to write the output trajectory (output.trj)
record.continuousNotrue to write the continuous trace (cont.trace)
record.discreteNotrue to write the discrete trace (disc.trace)
record.initNotrue to write the initialisation trace (init.trace)

The four record.* keys default to false, so a file that omits them loads with all four ticks cleared and the run writes nothing but its log. The three runtime.N rows default to empty, which is a row that plots nothing; a type with no name, or a name with no type, is an incomplete row rather than an error, and it is simply not plotted.

Booleans are true or false. Anything else is reported and the field is left at its default.

runtime.N.type stores the label shown in the dropdown, not a code: one of Bus Voltage, Machine Speed, Omega-delta of machine, Active power-delta of machine, Center of Inertia, Wall Time, Injector solutions, Latency, Branch Active Power Origin, Branch Active Power Extremity, Branch Reactive Power Origin, Branch Reactive Power Extremity, Injector Observable, Two-port injector Observable. A label this build does not know is reported and that row is left empty.

Loading is tolerant; running is not. These are checked when you press Run, not when the file is loaded, so a .cfg missing one of them loads without a word and then refuses to start:

  • At least one data.N. Both the dynamic simulation and the power flow refuse a case with no system data at all.
  • disturbance, to simulate. A dynamic run needs one; a power flow does not. The .dst must also end in a STOP record, which is checked when the run starts rather than when the path is set, because the file can be edited in between.
  • observables.file, whenever record.trajectory is true. The trajectory needs something to say which quantities it should contain. Setting record.trajectory = true with no observables file is the one combination that is refused outright.

diagram is needed only by the power flow’s one-line diagram output, and only when it is set; an unreadable template stops that run, an absent one does not.

A scenario records which files a case is made of, and nothing about the session it was saved in. Absent by design, not by omission:

  • The Analysis tab’s small-signal parameters, the working directory and the window geometry. A run does not depend on them.
  • Show observable dialog, and the eight picker lists behind it. The lists are session state that no .cfg has ever carried, so saving the tick alone restored a choice whose other half was gone: the tab came back ticked over eight empty lists. The tick is left exactly as you set it when a configuration is loaded.

Two key names retired with that last change. A file saved by STEPSS 3.81 or earlier may carry them, and both now get one sentence in the load report and are otherwise ignored:

Retired keyWhat happened to it
record.dumpRenamed record.init, matching the init.trace it writes
observables.wizardDropped; see above

Nothing else about such a file is affected, and re-saving the scenario writes it without them.

A path inside the .cfg’s own folder is stored relative to it, with forward slashes on every platform. Anything outside that folder is stored absolute. Relative paths are resolved against the .cfg’s directory, never against the working directory, and never leave the file: everything downstream of a load sees an absolute path.

That rule is what makes a case folder portable. Keep the .cfg beside the data it names and the whole folder can be moved, copied or sent to a colleague. A path that would need .. to express is stored absolute instead, so a file outside the folder is never silently repointed at a different one after a move.

A Kundur two-area case, saved beside its data:

# STEPSS scenario. Save configuration wrote this; Load configuration reads it.
# Paths inside this file's own directory are stored relative to it, so the
# folder can be moved or copied whole. Everything else is absolute.
# Saved by STEPSS 3.81
stepss.format = 1
# System data
data.1 = lf.dat
data.2 = dyn.dat
data.3 = solveroptions.dat
disturbance = disturb.dst
diagram = kundur.svg
# Observables
observables.file = obs.dat
runtime.1.type = Bus Voltage
runtime.1.name = 9
runtime.2.type = Machine Speed
runtime.2.name = G1
runtime.3.type =
runtime.3.name =
# Recording
record.trajectory = true
record.continuous = false
record.discrete = false
record.init = false

The section comments and the blank lines are for the reader. Nothing depends on them and a file without them loads identically.

Loading is deliberately tolerant, and a hand-written file benefits from the same rule: apply every key you understand and report the rest, rather than refusing the file over one bad line. A key nobody knows, a boolean that is not a boolean, an observable label that has been retired, a file that has since been deleted: each is one sentence to the user, and the rest of the scenario still loads.

Only three things are fatal, and all three are about the format number:

stepss.formatOutcome
AbsentRefused, as not being a scenario file
Not a numberRefused, as not being a scenario file
Higher than this build readsRefused, naming the version needed